Configuration Failure Alarm

Alarm Identifier LTC-011
Description Configuration failed. Reboot the AP or factory reset for a system initiated retry. Failed parameters: <%Parameter Name%>
Details
Additional Information Alarm is triggered when AP does not accept a configuration that is created on the tenant portal.
Specific Problem
Perceived Severity Critical
Action to clear alarm Switch off the LTE AP and switch it on.
Entered Event Exit Event Probable Cause System Action Additional Text
When a configuration fails on an AP. When a configuration is sent to an AP again. It may be due to AP reboot, factory reset or a configuration change on the tenant portal. Internal conflict of configuration parameters. Configuration change, a reboot or factory reset of AP is required. Any of these actions will trigger configuration re-try.