Configuration Failure Alarm

Alarm Identifier LTC-011
Description Configuration failed. Reboot the AP or factory reset for a system initiated retry. Failed parameters: <%Parameter Name%>
Details
Additional Information Alarm is triggered when AP does not accept a configuration that is created on the tenant portal.
Specific Problem —
Perceived Severity Critical
Action to clear alarm Switch off the LTE AP and switch it on.
Entered Event Exit Event Probable Cause System Action Additional Text
When a configuration fails on an AP. When a configuration is sent to an AP again. It may be due to AP reboot, factory reset or a configuration change on the tenant portal. Internal conflict of configuration parameters. Configuration change, a reboot or factory reset of AP is required. Any of these actions will trigger configuration re-try. —